Specifications
Product Details
LKM 282 Digital Programmable Measuring Transducer
An added benefit to all users is that this measuring transducer can be programmed for a variety of thermocouples all to DIN EN 60584-3.The sensors thermoelectric emfs are converted temperature linearly into the output signal which ranges from 0 to 10V. This is where temperature compensation takes place within the measuring transducer which is configured via a micro USB port.
Span: 50K
Linearity error: 0.3K
Measurement error: 0.2%
Error of reference junction: +/- 0.5°C
Supply voltage: 8 to 35 VDC, 8 to26 VAC polarity-safe
Max. current consumption: 15mA at 24VDC
Galvanic isolation: 2.5kV
Output: 0 to10V / 10 to 0V current-limited (1mA)
Sensor break: 10V typically 11V
Short circuit: voltage value for room temperature
Response time: 0.5s
TC: 100ppm/K
Humidity: 95%
Mounting: 35mm DIN-rail
Material: polyester
Dimensions: 100x6x93mm (HxWxD)
Type of terminals: screw terminals spring-cage terminals are possible
Clamping range: 0.2 to 2.5mm²
Weight: approx.54g
Vibration: 147 to 500Hz / 300 m/s² 500Hz to 2K / 200 m/s²
Galvanically Isolated Digital Programmable Measuring Transducer
Approvals
EN61326-2-3:2006